Laurel Electronics provides
digital panel meters / controllers, totalizers, counters, loop-powered meters,
temperature meters, for all types of transducers or process indication &
control. |
|
|
|
|
Laureate™
Pulse Input Batch Controller
With three
relay outputs for automated batch control
|
 |
|
|
|
|
Features |
|
Standard
Counter |
6-digit
display scalable to ±999,999 |
Selectable
display of batch total, grand total
or number of batches, and rate. |
Single
10 A relay for batch total, with settable delay between
cycles. |
Two
optional additional relays assignable to batch total
for prewarn, grand total or number of batches,
and rate. |
Count
up from 0 to preset or down from preset to 0. |
Frequency
input from 0 Hz to 1 MHz. |
Signals
from turbine flowmeters, magnetic pickups, NPN or PNP
transistors, digital logic, or AC from 12 mV to 250
Vac. |
Selectable
"count by" of 10 or 100 with rounding. |
Isolated
5, 10 or 24 Vdc excitation supply to power sensors. |
NEMA-4X
(IP-65) front panel, 1/8 DIN case. |
Optional
RS-232/485 I/O |
Certified
to UL 3101-1, CAN/CSA-C22.2, EN 61010-1 (CE Mark) |
Click
to Order Pulse Input Batch Controller
|
|
|
Description |
|
The
Laureate batch controller is a powerful and highly accurate
production workhorse in the form of a compact 1/8 DIN
panel meter. It can display the current batch total
(Item #1), grand total or number of batches (Item #2),
and flow rate (Item #3). All displayed values are scaled
to engineering units of volume or flow.
The batch controller utilizes the Extended counter main
board and FR dual channel signal conditioner board to
accept a wide range of pulse signals, in particular
those from turbine flowmeters. The same signal is applied
in parallel to the A and B channels
A 10 A contact relay serves as the batch relay to control
repetitive fill operations. It repeats the batch cycles
continually with a programmable delay from 10 ms to
199.99 sec, or based on an external control input. The
batch total (Item #1) can be set up to count up from
zero to a preset limit, or down from a preset limit
to zero. The single-relay board fits in the slot which
would otherwise be available for the analog output board.
An optional dual relay board (10 A contact or 0.12 A
AC/DC solid state relays) is normally used. Either relay
can be assigned to the batch total (Item #1) to serve
as a pre-warn to slow down filling near the setpoint,
to the grand total or number of batches (Item #2), or
to flow rate (Item #3).
An optional RS-232 or RS-485
board allows the batch controller to transmit Items
#1, #2 and #3, as well as peak for #3 (rate). If required,
all four items can be displayed simultaneously by augmenting
the batch controller with up to three Laureate remote
displays. Each of these can have its own analog output
and dual relays for alarm or control.
|

|
|
| Fast,
High Accuracy Measurement |
Flowmeter
Signal Conditioner |
| The
A and B channels of the FR dual-channel signal conditioner
are used independently. Either channel can accept pulse
rates from 0.005 Hz to 250 kHz, which exceeds the working
range of turbine flowmeters.
Channel A is used for totalizing. The measured total
is scaled mathematically for control and display in
engineering units, such as liters
Channel B is used for rate. The pulse frequency is determined
by timing an integral number of periods over a specified
gate time (plus 30 ms and 0-2 periods), and then taking
the inverse of period. The inverse period approach allows
much greater accuracy and faster update times than conventional
rate meters which count signal pulses over a specified
time interval. Update times can be as high as 25/sec.
Rate in engineering units, such as liters per second,
is obtained by multiplying the input by a scale factor.
For either total or rate, displayed values can be up
to six digits (999,999) with a selectable decimal point. |
The
FR dual-channel signal conditioner accepts pulses from
all types of turbine flowmeters and most industrial
transducers with a pulse output such as proximity switches
with PNP or NPN output, TTL or CMOS logic, magnetic
pickup pulses down to 12 mV, as well as AC inputs up
to 250 Vac.
Nine hysteresis and input levels are jumper selectable
for reliable measurements at different signal levels.
A 1600 Hz low-pass rolloff filter for noise reduction
is selectable
A built-in isolated 5, 10, or 24 Vdc excitation supply
can power proximity switches and other sensors, and
eliminate the need for an external power supply. |
| Other
Features |
| Laureate
meters and counters meet NEMA 4X (IP-65) standards from
the front for high pressure washdown when panel mounted.
All power and signal connections are via UL / VDE /
CSA rated screw clamp plugs, which are standard
|
Click
to Order Pulse Input Batch Controller
|
|
| Specifications |
| Display |
Excitation
Output |
Readout |
6
digits, 7-segment, 14.2 mm (.56") |
5
Vdc |
5
Vdc ±5%, 100 mA max |
Color |
Red
or green LED |
10
Vdc |
10
Vdc ±5%, 120 mA max |
Range |
-99999
to +99999 XXXXEX scientific notation beyond 999999 |
24
Vdc |
24
Vdc ±5%, 50 mA max
|
Indicators |
4
red LED lamps |
Output
isolation |
50
Vdc to meter ground |
Accuracy |
Electrical
Connections |
Time
Base |
Crystal
calibrated to ±2 ppm |
|
Span
Tempco |
±1
ppm/°C (typ) |
Long-term
Drift |
±5
ppm/year |
Conversion |
Power |
Frequency
Technique |
Inverse
period |
Voltage,
std.
|
85-264
Vac and 90-370 Vdc
|
Conversion
Time |
Gate
time + 30 ms+ 0-2 signal periods |
Frequency
|
DC
or 49-440 Hz
|
Gate
Time |
Selectable
10 ms to 199.99 s |
Voltage,
opt. |
8-28
Vac and 9-37 Vdc
|
Timeout
|
Selectable
10 ms to 199.99 s
|
Power
isolation |
Safety-rated
to 250 Vac, meter ground to earth ground,
DC to 60 Hz, 4.2 kVp per High Voltage Test |
Output
& Display Updates |
Same
as conversion time |
|
|
Inputs |
Types
|
Pulses
from NPN, PNP transistors, contact closures, magnetic
pickups, AC |
Selectable
Hysteresis |
(-12
mV to +12 mV), (+30 mV to +60 mV),
(-30 mV to -20 mV), (-150 mV to +150 mV),
(+350 mV to +600 mV), (-600 mV to -350 mV),
(-1.15 V to +1.15 V), (+1.25 V to +2.1 V), |
Signal
ground |
Common
ground for channels A & B |
Channel
A Frequency |
0
Hz to 1 MHz (totalizing), 0.005 Hz to 1 MHz (rate) |
Rolloff
Filter |
(-2.1
V to -1.25 V) |
Channel
B Frequency |
0
Hz to 250 kHz (totalizing), 0.005 Hz to 250 kHz (rate |
Debounce
Time |
Selectable,
none or 1600 Hz
Selectable 0, 3, 50 ms |
| Environmental |
Rate
Conversion |
Operating
Temperature |
0°C
to 55°C |
Frequency
Technique |
Inverse
period |
Storage
Temperature |
-40°C
to 85°C |
Delay
between batch cycles |
Selectable
10 ms to 199.99 s |
Relative
Humidity |
95%
at 40°C, non-condensing |
Display
Update Time |
Same
as conversion time |
Protection |
NEMA-4X
(IP-65) when panel mounted |
Output
Update Time |
Same
as conversion time |
Click
to Order Pulse Input Batch Controller
|
|
|
Controlling
the Mixing of Materials |
|
Typical
Applications |
|
Drum
Filling Application Utilizing Three Relay Outputs |
|
|
In
this drum filling application, the Laureate utilizes
its maximum of three relays to control the pump.
The Prewarn relay slows down the pump near the preset
to avoid overshoot. The Batch relay stops the pump
at the preset. The Grand Total relay stops the filling
operation once a predetermined number of drums have
been filled.
|
|
Multiple
Laureate batch controllers can be used in combination
to control the mixing of materials in the proper
ratio. Each feed line is equipped with its own pump,
flowmeter, and Laureate.
Controller setup and monitoring of the mixing operation
are facilitated by optional serial communications.
RS-485 allows a single data line to handle multiple
controllers. |
|
Up-Counting
Batch Control |
Down-Counting
Batch Control |
|
In
up-counting batch control, the Laureate counts up
from zero to a preset maximum. A prewarn level is
available to slow down filling near the preset to
avoid overshoot. A time delay can be programmed
from the end of each batch to the start of the next
batch. |
|
In
down-counting batch control, the Laureate counts
down from the preset maximum to zero. A prewarn
level is available to slow down filling or emptying
near zero. Again, a time delay can be programmed
from the end of each batch to the start of the next
batch. |
|
Discrete
Filling and Batch Counting |
|

|
The
Laureate batch controller is ideal for discrete
manufacturing as well as repetitive fill operations.
In this example, the Laureate counts bottles which
it then groups into sixpacks. Its Grand Total capability
can be used to track bottles or sixpacks. |